Equipment technical parameters
|
Weighing range |
Within 30Kg |
|
Weighing accuracy |
±20g |
|
Conveying size (for reference only, adjusted according to customer size) |
Buffer section: length: 800mm width: 600mm; Weighing section: length: 900mm width: 600mm; Rejection section: length: 1000mm width: 600mm;
|
|
Display resolution |
5g |
|
Sorting speed |
100 bags/hour Adjustable speed |
|
Conveyor belt height from ground |
750±50mm(need to be confirmed) |
|
Conveying direction |
Facing the operation interface from left to right (need to be confirmed) |
|
Power supply voltage |
AC 220V (fluctuation +10%, -15%, 50/60 hz) |
|
Working temperature |
From 0°C to 40°C |
|
Humidity |
90% Relative humidity (no condensation) |
|
Material of the scale body |
Made of 304 stainless steel, square tube |
|
Rejection method |
Push rod type rejection |
Equipment workflow
The product is transported to the "weight detector" through the previous assembly line.
1. The product enters the "weighing section" of the weighing machine: the weighing system quickly detects the weight of the product; and immediately determines whether the product weight is within the target weight range. If the product weight is qualified, it will be correctly transmitted out of the weighing machine; if the product weight is unqualified, an alarm will be sounded and a reminder or shutdown will be issued. At the same time, the system will automatically record the number of qualified products and the number of unqualified products.
2. The product enters the "rejection section" of the weighing machine: when the rejection section detects the rejection delay signal, it will make a rejection action in a timely manner to accurately reject unqualified products.